| ROOM #1 | WALL - OUTSIDE | WINDOWS - OUTSIDE | DOOR - OUTSIDE | |||||||||||
| k | 15 | k | 10 | k | 5 | |||||||||
| S(door) | 2 | dT | 35 | dT | 35 | dT | 35 | |||||||
| S(window) | 2 | thickness | 20 | thickness | 1 | thickness | 5 | Furnace | ||||||
| S(wall-outside) | 27 | Q(wa-o) | 708.75 | Q(win-o) | 1400 | Q(d-o) | 70 | P1 | 2178.75 | |||||
| ROOM #2 | WALL - OUTSIDE | WINDOWS - OUTSIDE | DOOR - OUTSIDE | |||||||||||
| k | 15 | k | 10 | k | 5 | |||||||||
| S(door) | 0 | dT | 35 | dT | 35 | dT | 35 | |||||||
| S(window) | 2 | thickness | 20 | thickness | 1 | thickness | 5 | Furnace | ||||||
| S(wall-outside) | 29 | Q(wa-o) | 761.25 | Q(win-o) | 1400 | Q(d-o) | 0 | P2 | 2161.25 | |||||
| K( wall 1 - 0) | 20.25 | big K's are computed the same as Q's but without multiplying by dT | ||||||||||||
| K( window 1 - 0) | 40 | |||||||||||||
| K( door 1 - 0) | 2 | Equations (PART 2): findinf T1, T2 when P1, P2 are known | ||||||||||||
| K( wall 1 - 2) | 9.75 | Room1: | P1 = Kw10(T1-T0) + Kwin10(T1-T0) + Kd10(T1-T0) + Kw12(T1-T2) + Kd12(T1-T2) | |||||||||||
| K( door 1 - 2) | 2 | Room2: | P2 = Kw20(T2-T0) + Kwin20(T2-T0) + Kw21(T2-T1) + Kd21(T2-T1) | |||||||||||
| K( wall 2 - 0) | 21.75 | |||||||||||||
| K( window 2 - 0) | 40 | Room1: | 3000 = 20.25*(T1+10) + 40*(T1+10) + 2*(T1+10) + 9.75*(T1-T2) + 2*(T1-T2) | |||||||||||
| K( wall 2 - 1) | 9.75 | Room2: | 3000 = 21.75*(T2+10) + 40*(T2+10) + 9.75*(T2-T1) + 2*(T2-T1) | |||||||||||
| K( door 2 - 1) | 2 | (assuming outside temperature T0=-10, and P1=P2=3 kW) | ||||||||||||
| Indexes: | 1 - room 1 | |||||||||||||
| 2 - room 2 | ||||||||||||||
| 0 - outside | ||||||||||||||